Measure surfaces without contact and over an area—from topography to standards-based roughness evaluation.
Testing service · Optical 3D surface measurement
High-precision interferometer measurement with Vertical Scanning Interferometry
Testawell structures interferometric measurement from feasibility to an evaluable 3D height field. VSI or CSI reveals roughness, steps, form deviations and local surface features without contact.
What is an interferometer for 3D surface measurement?
An optical interferometer splits light into measurement and reference paths. Recombination creates an interference signal whose position contains information about the optical path to the surface. With a camera and precise Z movement, an interferometric microscope produces an areal height field z(x,y).
Vertical Scanning Interferometry is also known as Coherence Scanning Interferometry (CSI) or white-light interferometry. Quantitative data require field, objective, surface, filters and evaluation to be matched to the task.
How does Vertical Scanning Interferometry work?
A broadband source illuminates measurement and reference surfaces. During a vertical scan, the camera records images. A strong local signal occurs when optical path lengths lie within the coherence range. Its Z position gives the height for each evaluable pixel.
Illuminate and split the measurement and reference paths.
Scan vertically through the coherence range.
Locate the signal for each camera pixel.
Build the topography as an areal 3D dataset.
Evaluate form, filters, area and parameters.
The signal results from superposition of reference and measurement paths.
Which quantities can be derived from 3D topography?
Task
Typical output
Key definition
Surface topography
3D field, profiles, sections, false colour and local features
Field, sampling, objective and missing points
Areal roughness
S-parameters and functional ISO 25178 evaluation
S/L filters, area and form removal
Profile roughness
Extracted profiles and agreed parameters
Direction, length, filter and profile standard
Steps and depressions
Step height, depth, area or volume
References, edges, tilt and uncertainty
Form and waviness
Flatness, curvature and local deviations
Reference geometry and spatial filtering
From the surface to a defensible result
01
Define the question
Function, feature, tolerance, standard and required statement are clarified.
02
Check feasibility
Geometry, access, reflection, roughness, slopes and layers are assessed.
03
Set the strategy
Objective, scan range, field, repeats, references, stitching and filters are agreed.
04
Evaluate the data
Topography, profiles, values, visualisations and conditions are combined.
VSI, PSI, confocal measurement or stylus profilometry?
Method
Strengths
Check carefully
VSI / CSI
Non-contact areal height field for technical surfaces and steps
Steep slopes, reflectivity, layers, vibration and missing points
PSI
Very high vertical sensitivity on smooth stable surfaces
Phase ambiguity, range and stability
Confocal / focus variation
Larger height ranges and structured geometry
Resolution, contrast and method artefacts
Stylus
Established profile route linked to many drawings
Tip geometry, contact and no areal information
Which limits and uncertainties matter?
Instrument resolution is not the uncertainty on a real component. Objective, numerical aperture, scanning, calibration, environment, slope, reflectivity, filtering and algorithms affect the result. Comparable work documents conditions, cleaning, form removal, filters and missing-point handling.
What does Testawell need for an enquiry?
component, material and surface state
location, size and accessibility
roughness, step or expected height range
parameters, tolerances, drawing and standard
locations, variants and repeats
required raw data, views, profiles, values or report
Frequently asked questions about interferometers and VSI
What is Vertical Scanning Interferometry?
VSI is a non-contact optical method for areal 3D surface measurement. During a Z scan, the position of the interference signal is evaluated for each camera pixel. It is also called Coherence Scanning Interferometry or white-light interferometry.
What does an interferometer measure on a surface?
The areal height field can be used to evaluate topography, roughness, waviness, step height, flatness, volume and further geometry. Parameters, filters and evaluation area must be defined for the task.
Is VSI the same as white-light interferometry?
VSI, scanning white-light interferometry and CSI are often used for closely related methods. CSI is the more precise metrological term for locating the interference signal during an optical path-length scan.
When is optical measurement preferable to tactile roughness measurement?
VSI is valuable when a sensitive surface must be measured without contact and as an area. A tactile method may be preferable if the drawing explicitly requires a profile parameter or stylus method.
Which surfaces are difficult for interferometric measurement?
Very steep slopes, multiple reflections, transparent layers, contamination, poor optical access and large reflectivity differences can create missing or ambiguous points.
Which data are needed for an enquiry?
Provide component or specimen, material and surface condition, approximate area, expected height range, required parameters, drawing or standard, number of locations and desired documentation.